• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar

information for practice

news, new scholarship & more from around the world


advanced search
  • gary.holden@nyu.edu
  • @ Info4Practice
  • Archive
  • About
  • Help
  • Browse Key Journals
  • RSS Feeds

Meditators Probably Show Increased Behaviour-Monitoring Related Neural Activity

Abstract

 

Objectives

Mindfulness meditation is associated with better attention function. Performance monitoring and error-processing are important aspects of attention. We investigated whether experienced meditators showed different neural activity related to performance monitoring and error-processing. Previous research has produced inconsistent results. This study used more rigorous analyses and a larger sample to resolve the inconsistencies.

 

Method

We used electroencephalography (EEG) to measure the error-related negativity (ERN) and error positivity (Pe) following correct and incorrect responses to a Go/Nogo task from 27 experienced meditators and 27 non-meditators.

 

Results

No differences were found in the ERN (all p > 0.05). Meditators showed larger global field potentials (GFP) in the Pe after correct responses and errors, indicating stronger neural responses (p = 0.019, FDR-p = 0.152, np2 = 0.095, BFincl = 2.691). This effect did not pass multiple comparison controls. However, single-electrode analysis of the Pe did pass multiple comparison controls (p = 0.002, FDR-p = 0.016, np2 = 0.133, BFincl = 220.659). Meditators also showed a significantly larger Pe GFP for errors, which would have passed multiple comparison controls, but was not a primary analysis (p = 0.003, np2 = 0.149, BF10 = 9.999).

 

Conclusions

Meditation may strengthen neural responses related to performance monitoring. However, these strengthened neural responses were not specific to error monitoring (although the error-related Pe may be more sensitive to group differences than the correct response Pe). These conclusions remain tentative, because the single-electrode analysis passed multiple comparison controls, but the analysis including all electrodes did not.

 

Preregistration

This study was not preregistered.

 

Read the full article ›

Posted in: Journal Article Abstracts on 02/15/2023 | Link to this post on IFP |
Share

Primary Sidebar

Categories

Category RSS Feeds

  • Calls & Consultations
  • Clinical Trials
  • Funding
  • Grey Literature
  • Guidelines Plus
  • History
  • Infographics
  • Journal Article Abstracts
  • Meta-analyses - Systematic Reviews
  • Monographs & Edited Collections
  • News
  • Open Access Journal Articles
  • Podcasts
  • Video

© 1993-2025 Dr. Gary Holden. All rights reserved.

gary.holden@nyu.edu
@Info4Practice