Pharmacokinetics of a novel, approved, 1.4‐mg intranasal naloxone formulation for reversal of opioid overdose—a randomized controlled trial

Abstract

Background and aims

Intranasal (i.n.) naloxone is an established treatment for opioid overdose. Anyone likely to witness an overdose should have access to the antidote. We aimed to determine whether an i.n. formulation delivering 1.4 mg naloxone hydrochloride would achieve systemic exposure comparable to that of 0.8 mg intramuscular (i.m.) naloxone.

Design

Open, randomized four‐way cross‐over trial.

Setting

Clinical Trials Units in St Olav’s Hospital, Trondheim and Rikshospitalet, Oslo, Norway.

Participants

Twenty‐two healthy human volunteers, 10 women, median age = 25.8 years.

Intervention and comparator

One and two doses of i.n. 1.4 mg naloxone compared with i.m. 0.8 mg and intravenous (i.v.) 0.4 mg naloxone.

Measurements

Quantification of plasma naloxone was performed by liquid chromatography tandem mass spectrometry. Pharmacokinetic non‐compartment analyses were used for the main analyses. A non‐parametric pharmacokinetic population model was developed for Monte Carlo simulations of different dosing scenarios.

Findings

Area under the curve from administration to last measured concentration (AUC0‐last) for i.n. 1.4 mg and i.m. 0.8 mg were 2.62 ± 0.94 and 3.09 ± 0.64 h × ng/ml, respectively (P = 0.33). Maximum concentration (Cmax) was 2.36 ± 0.68 ng/ml for i.n. 1.4 mg and 3.73 ± 3.34 for i.m. 0.8 mg (P = 0.72). Two i.n. doses showed dose linearity and achieved a Cmax of 4.18 ± 1.53 ng/ml. Tmax was reached after 20.2 ± 9.4 minutes for i.n. 1.4 mg and 13.6 ± 15.4 minutes for i.m. 0.8 mg (P = 0.098). The absolute bioavailability for i.n. 1.4 mg was 0.49 (±0.24), while the relative i.n./i.m. bioavailability was 0.52 (±0.25).

Conclusion

Intranasal 1.4 mg naloxone provides adequate systemic concentrations to treat opioid overdose compared with intramuscular 0.8 mg, without statistical difference on maximum plasma concentration, time to maximum plasma concentration or area under the curve. Simulations support its appropriateness both as peer administered antidote and for titration of treatment by professionals.

Read the full article ›

Posted in: Journal Article Abstracts on 03/03/2019 | Link to this post on IFP |
Share

Primary Sidebar

Categories

Category RSS Feeds

  • Calls & Consultations
  • Clinical Trials
  • Funding
  • Grey Literature
  • Guidelines Plus
  • History
  • Infographics
  • Journal Article Abstracts
  • Meta-analyses - Systematic Reviews
  • Monographs & Edited Collections
  • News
  • Open Access Journal Articles
  • Podcasts
  • Video

© 1993-2026 Dr. Gary Holden. All rights reserved.

gary.holden@nyu.edu
@Info4Practice